Review




Structured Review

DiscoverX corporation pathhunter® prolabel® detection kit
Pathhunter® Prolabel® Detection Kit, supplied by DiscoverX corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pathhunter+detection+kit/pathhunter+prolabel+detection+kit/pm40639372-211-86-91
Average 90 stars, based on 1 article reviews
pathhunter® prolabel® detection kit - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Incubation:

Article Title: Phosphorylation patterns in the AT1R C-terminal tail specify distinct downstream signaling pathways.
Article Snippet: Different ligands stabilize specific conformations of the angiotensin II type 1 receptor (AT1R) that direct distinct signaling cascades mediated by heterotrimeric G proteins or βarrestin.. These different active conformations are thought to engage distinct intracellular transducers because of differential phosphorylation patterns in the receptor Cterminal tail (the “barcode” hypothesis).. Here, we identified the AT1R barcodes for the endogenous agonist AngII, which stimulates both G protein activation and βarrestin recruitment, and for a synthetic biased agonist that only stimulates βarrestin recruitment.

Article Title: Phosphorylation patterns on the AT1R C-terminal tail specify distinct downstream signaling pathways
Article Snippet: .. Following the addition of reagents from the PathHunter Detection kit (DiscoverX) and an additional 1-hour incubation at room temperature, chemiluminescence arising from the complementation of β-galactosidase fragments (Enzyme Acceptor and ProLink) within endosomes due to β-arrestin endocytosis was detected on a Neo2 (BioTek) microplate reader. β-arrestin1 Endocytosis BRET Assay The level of β-arrestin1 endocytosis was measured by the endocytosis BRET assay as described with minor modifications[ 64 ]. ..

Article Title: Structural and functional determination of peptide versus small molecule ligand binding at the apelin receptor
Article Snippet: .. Compounds were incubated for 1.5 h together with [Pyr1]-apelin 13 as a reference and β-Arrestin accumulation detected using the PathHunter Detection Kit according to the recommended protocol (https://cf-ecomproducts.discoverx.com/download/Products/UserManual/eXpressKits/70-255_PathHunter_BArrestin_eXpress_GPCR_Assay.pdf). .. Inhibition of cAMP signalling by cells expressing the apelin receptor was determined using the cAMP HunterTM eXpress AGTRL1 CHO-K1 GPCR Assay (Eurofins, Catalog # 95-0147E2CP2M).

Article Title: Systematic pharmacological analysis of agonistic and antagonistic fibroblast growth factor receptor 1 MAbs reveals a similar unique mode of action
Article Snippet: Engineered U2OS cells expressing ProLink (PK)-tagged FGFR1 and an enzyme acceptor–tagged PLCγ1 (DiscoverX) were plated (40,000 cells/well) in a 384-well plate and incubated overnight at 37 °C, 5% CO 2 . .. After a 24 h incubation, cells were cultured with FGF ligand and/or FGFR1 Abs diluted in DiscoverX-recommended medium for 22 h. Following stimulation, signal was detected using the PathHunter Detection Kit according to the recommended protocol. .. The signal was recorded with a CLARIOstar reader (BMG LABTECH).

Article Title: Co-Expression of GRK2 Reveals a Novel Conformational State of the µ-Opioid Receptor
Article Snippet: .. The agonist-loaded cell plates were then incubated at 37°C for 90 minutes, before detection of the β-arrestin receptor interaction using the DiscoveRx PathHunter detection kit (DiscoveRx, Birmingham, UK) according to the manufacturer's instructions. .. The agonist-loaded cell plates were then incubated at 37°C for 90 minutes, before detection of the β-arrestin receptor interaction using the DiscoveRx PathHunter detection kit (DiscoveRx, Birmingham, UK) according to the manufacturer's instructions.

other:

Article Title: Phosphorylation patterns on the AT1R C-terminal tail specify distinct downstream signaling pathways
Article Snippet: β-arrestin2 endocytosis was measured by the active endocytosis assay (DiscoverX) as described[ 30 ] with slight modifications.

Bioluminescence Resonance Energy Transfer:

Article Title: Phosphorylation patterns on the AT1R C-terminal tail specify distinct downstream signaling pathways
Article Snippet: .. Following the addition of reagents from the PathHunter Detection kit (DiscoverX) and an additional 1-hour incubation at room temperature, chemiluminescence arising from the complementation of β-galactosidase fragments (Enzyme Acceptor and ProLink) within endosomes due to β-arrestin endocytosis was detected on a Neo2 (BioTek) microplate reader. β-arrestin1 Endocytosis BRET Assay The level of β-arrestin1 endocytosis was measured by the endocytosis BRET assay as described with minor modifications[ 64 ]. ..

Lysis:

Article Title: Humanized antibodies with ultralong complementary determining regions
Article Snippet: The DiscoveRx cells are engineered such that upon activation by ligand, the resultant beta-arrestin recruitment to the GPCR also causes activation of a luminescent reporter enzyme present cell line. .. Lysis reagents and luminescence substrate are included in the PathHunter Detection Kit (Cat #93-001, DiscoveRx) which was used following manufacturer's instructions. ..

Cell Culture:

Article Title: Systematic pharmacological analysis of agonistic and antagonistic fibroblast growth factor receptor 1 MAbs reveals a similar unique mode of action
Article Snippet: Engineered U2OS cells expressing ProLink (PK)-tagged FGFR1 and an enzyme acceptor–tagged PLCγ1 (DiscoverX) were plated (40,000 cells/well) in a 384-well plate and incubated overnight at 37 °C, 5% CO 2 . .. After a 24 h incubation, cells were cultured with FGF ligand and/or FGFR1 Abs diluted in DiscoverX-recommended medium for 22 h. Following stimulation, signal was detected using the PathHunter Detection Kit according to the recommended protocol. .. The signal was recorded with a CLARIOstar reader (BMG LABTECH).



Similar Products

86
Eurofins pathhunter detection kit
Pathhunter Detection Kit, supplied by Eurofins, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pathhunter+detection+kit/detection+kit+pathhunter/pmc13139559-42-38-41
Average 86 stars, based on 1 article reviews
pathhunter detection kit - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
DiscoverX corporation pathhunter® prolabel® detection kit
Pathhunter® Prolabel® Detection Kit, supplied by DiscoverX corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pathhunter+detection+kit/pathhunter+prolabel+detection+kit/pm40639372-211-86-91
Average 90 stars, based on 1 article reviews
pathhunter® prolabel® detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
DiscoverX corporation pathhunter prolabel detection kit
Pathhunter Prolabel Detection Kit, supplied by DiscoverX corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pathhunter+detection+kit/pathhunter+prolabel+detection+kit/pmc12087876-87-0-5
Average 90 stars, based on 1 article reviews
pathhunter prolabel detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Eurofins pathhunter® detection kit
Pathhunter® Detection Kit, supplied by Eurofins, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pathhunter+detection+kit/pathhunter+detection+kit/pm39942708-230-22-25
Average 90 stars, based on 1 article reviews
pathhunter® detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Eurofins pathhunter ® detection kit
Pathhunter ® Detection Kit, supplied by Eurofins, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pathhunter+detection+kit/pathhunter+detection+kit/pmc11820436-146-22-26
Average 90 stars, based on 1 article reviews
pathhunter ® detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
DiscoverX corporation substrate prepared from the pathhunter flash detection kit
Substrate Prepared From The Pathhunter Flash Detection Kit, supplied by DiscoverX corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pathhunter+detection+kit/pathhunter+flash+detection+kit/us12201633-503-3-11
Average 90 stars, based on 1 article reviews
substrate prepared from the pathhunter flash detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
DiscoverX corporation pathhunter flash detection kit
Pathhunter Flash Detection Kit, supplied by DiscoverX corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pathhunter+detection+kit/pathhunter+flash+detection+kit/us12201633-516-19-23
Average 90 stars, based on 1 article reviews
pathhunter flash detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results